Keep Pipes from Freezing with Pipe Freeze PRO

Self-Regulating pipe-trace heat tape for use in protecting pipes from freezing. Pipe Freeze Pro Heat Tape is the highest-quality, most effective pipe freeze protection heat tape on the market. It saves you money in energy costs and unneeded replacement expenses. Protect your home from electrical fires: Safer fire precaution then leading heat tape.

Heat Tape for Pipes

Our Plug-in Pipe Freeze heat tape is designed for residential and commercial protection against frozen plumbing on pipes made from both metal (copper/iron) and plastic. Our cables are self-regulating, so they only ask for the power they need to heat the pipe above freezing. This saves you a lot of money in the long run by not wasting electricity like constant wattage Pipe Trace heat tape.

Each cable can simply connect to any grounded 120V receptacle. Also unlike cheap Pipe Freeze heat tape, our cables can be overlapped across itself without risk of overheating and/or burnout.

  • Self-Regulating – The cable regulates it’s temperature and power consumption, optimizing for the surrounding temperature. This uses less energy and save you money.
  • Since temperatures modulate, Pipe Freeze Pro will not overheat, or pose a risk of fire like other heat tape. Pipe Freeze Pro can overlap and touch itself. Standard heat tape can not do this.
  • Produces 6 watts per foot (at 50ºF) and 9.6 watts per foot (at 32ºF).
  • Suitable for metal or plastic pipes up to 6″ for pipe heat tracing applications.
  • ETL listed
  • 5-year manufacturer’s warranty

Please Note:

Pipe Freeze Pro is not designed to thaw frozen Pipes. It's designed to prevent pipes from freezing. If you have frozen pipes, call your local plumber to determine the best course of action.

 


Heat Tape Cable Lengths

The stated length of the cable is the heated, working part of the heat tape. There is an additional 4 feet of unheated, cold lead with a light-up plug. Add 4 feet to the stated length to determine the total length.


 

TECHNICAL INFO

Power Usage

Model

50°F

32°F

Length

HTP-120-006

36 watts

57 watts

6 ft

HTP-120-012

72 watts

114 watts

12 ft

HTP-120-018

108 watts

171 watts

18 ft

HTP-120-024

144 watts

228 watts

24 ft

HTP-120-037

225 watts

356 watts

37 ft

HTP-120-050

300 watts

475 watts

50 ft


Maximum Circuit Lengths - 120 Volt PipeFreeze PRO™ Heat Tape

For a detailed PDF manual on our PipeFreeze PRO heat tape click the following: 

HeatTape PRO Installation Manual

 



The table below indicates maximum circuit lengths for 120 volt PipeFreeze PRO heat cable at different start up temperatures. The figure in black represents the maximum length of a HeatTape PRO heat cable in feet.

Heat Cable Selection Start-up Temperature Breaker Sizes
15A 20 A 30A 40A

120 Volt

Self-Regulating PipeFreeze PRO™ (6 watts/ft)
50 10 200 ft 235 ft 245 ft 245 ft
32 0 200 ft 235 ft 245 ft 245 ft
14 -10 160 ft 200 ft 235 ft 245 ft
0 -18 125 ft 170 ft 235 ft 245 ft
-20 -29 110 ft 150 ft 220 ft 245 ft
-40 -40 100 ft 130 ft 195 ft 240 ft



WARRANTY

PipeFreeze PRO Manufacturer's Warranty

Radiant Solutions Company (the Company) warrants its electric self-regulating heat cable (the Product) to be free from defects in materials and workmanship for a period of 5 years to the first owner and/or original purchaser of the product. Warranty card must be registered with the company. Under this Limited Warranty, Radiant Solutions Company will provide the following: If the product is determined by the Company to be defective in materials and workmanship and has not been damaged as a result of abuse, misapplication or modi cation, the Company will refund all or part of the manufacturer’s published list price of the Product at the time of purchase. Radiant Solutions Company’s maximum liability shall not in any case exceed the list price for the product claimed to be defective. Warranty requires the installation be performed in strict accordance with the details outlined in this manual. Failure to do so voids the warranty completely. Radiant Solutions Company is not responsible for damage to product it deems the result of neglect, abuse or lack of maintenance. Purchaser is responsible for the costs associated with the installation, removal and reinstallation of the products including both labor and shipping costs incurred to return the product to Radiant Solutions Company. In order to make a claim, you must:

 

  1. Provide the Company with sufficient details relating to the nature of the defect, the installation, the history of operation and any repairs that may have been made.
  2. At the Company’s discretion and at the owner’s expense, ship the Product to the Company or the Company’s local distributor.
  3. Provide proof that the Product was installed in accordance with the applicable Product Installation Manual and any special written design or installation guidelines by Radiant Solutions Company for this project.
  4. Provide proof that the Product was installed in accordance with the National Electrical Code (NEC) or the Canadian Electrical Code, or all applicable local building and electrical codes.
  5. Provide a retail sales receipt or proof of purchase.

 

The following are not covered by this Limited Warranty:

  1. Any incidental or consequential damage, including inconvenience, loss of time or loss of income.
  2. Any labor or materials required to repair or replace the Product or controls.
  3. Any freight or delivery costs related to the Product to or from our facility.
  4. Any costs associated with the analysis needed to discover or diagnose a potential problem with the cable system.
  5. Radiant Solutions Company will not be responsible for consequential damages arising with respect to the product for any reason.

View the warranty and warranty registration on the PipeFreeze PRO website:


    Scroll to top