Login
Ice Dam Prevention Products  

Ice Dam Company Self Regulating Heat Cable

By Ice Dam Company

$ 3.23
per foot

This product is unavailable

OVERVIEW

Ice Dam Company’s self regulating heat cable ensures that your pipes remain clear of ice and water continues to flow all winter long. Easy installation makes the process go quickly so you can be prepared long before winter arrives. Perfect for residential, commercial or industrial applications.

SR Series Self-Regulating Heating Cable is designed for commercial and industrial ice dam prevention and pipe trace applications. The cable is constructed so that it will not burn out or overheat when overlapped, and can be used on metal and plastic pipes. The cable is cut to length for custom orders.

Backed by an unprecedented 5 Year Manufacturer's Warranty.

 

TECHNICAL DOCUMENTS

Maximum Circuit Lengths - 120 Volt Ice Dam Company Heat Cable

For a detailed PDF manual on Ice Dam Co. Heat Cable click the following:

Ice Dam Heat Cable Installation Manual

The table below indicates maximum circuit lengths for 120 volt 

Ice Dam Co. Heat Cable at different start up temperatures. The figure in black represents the maximum length of a heat cable in feet.

 

Heat Cable Selection Start-up Temperature Breaker Sizes
15A 20 A 30A 40A

120 Volt
Self-Regulating Ice Dam Co. Heat Cable (6 watts/ft)

50 10 200 ft 235 ft 245 ft 245 ft
32 0 200 ft 235 ft 245 ft 245 ft
14 -10 160 ft 200 ft 235 ft 245 ft
0 -18 125 ft 170 ft 235 ft 245 ft
-20 -29 110 ft 150 ft 220 ft 245 ft
-40 -40 100 ft 130 ft 195 ft 240 ft

 

 

Maximum Circuit Lengths - 240 Volt Ice Dam Company Heat Cable

For a detailed PDF manual on ourIce Dam Co. Heat Cable click the following:

Ice Dam Heat Cable Installation Manual

The table below indicates maximum circuit lengths for 240 volt

Ice Dam Co. Heat Cable at different start up temperatures. The figure in black represents the maximum length of a heat cable in feet.

 

Heat Cable Selection Start-up Temperature Breaker Sizes
15A 20A 30A 40A

240 Volt
Self-Regulating Ice Dam Co. Heat Cable (6 watts/ft)

50 10 405 ft 470 ft 490 ft 490 ft
32 0 405 ft 470 ft 490 ft 490 ft
14 -10 320 ft 400 ft 475 ft 490 ft
0 -18 255 ft 340 ft 475 ft 490 ft
-20 -29 225 ft 300 ft 440 ft 490 ft
-40 -40 195 ft 260 ft 400 ft 480 ft

WARRANTY

Ice Dam Company HeatCable PRO
Radiant Solutions Company Manufacturer's Warranty

Radiant Solutions Company (the Company) warrants its electric self-regulating heat cable (the Product) to be free from defects in materials and workmanship for a period of 5 years to the first owner and/or original purchaser of the product. Warranty card must be registered with the company. Under this Limited Warranty, Radiant Solutions Company will provide the following: If the product is determined by the Company to be defective in materials and workmanship and has not been damaged as a result of abuse, misapplication or modi cation, the Company will refund all or part of the manufacturer’s published list price of the Product at the time of purchase. Radiant Solutions Company’s maximum liability shall not in any case exceed the list price for the product claimed to be defective. Warranty requires the installation be performed in strict accordance with the details outlined in this manual. Failure to do so voids the warranty completely. Radiant Solutions Company is not responsible for damage to product it deems the result of neglect, abuse or lack of maintenance. Purchaser is responsible for the costs associated with the installation, removal and reinstallation of the products including both labor and shipping costs incurred to return the product to Radiant Solutions Company. In order to make a claim, you must:

 

  1. Provide the Company with sufficient details relating to the nature of the defect, the installation, the history of operation and any repairs that may have been made.
  2. At the Company’s discretion and at the owner’s expense, ship the Product to the Company or the Company’s local distributor.
  3. Provide proof that the Product was installed in accordance with the applicable Product Installation Manual and any special written design or installation guidelines by Radiant Solutions Company for this project.
  4. Provide proof that the Product was installed in accordance with the National Electrical Code (NEC) or the Canadian Electrical Code, or all applicable local building and electrical codes.
  5. Provide a retail sales receipt or proof of purchase.

 

The following are not covered by this Limited Warranty:

  1. Any incidental or consequential damage, including inconvenience, loss of time or loss of income.
  2. Any labor or materials required to repair or replace the Product or controls.
  3. Any freight or delivery costs related to the Product to or from our facility.
  4. Any costs associated with the analysis needed to discover or diagnose a potential problem with the cable system.
  5. Radiant Solutions Company will not be responsible for consequential damages arising with respect to the product for any reason.

View the warranty and warranty registration on the Heat Tap PRO website: